Why Polypropylene Smears on Normal Mills—and Jeton's Fix
PP combines a low melting point (~165°C) with high thermal expansion and elastic spring-back. Dull endmills rub rather than shear, melting PP onto the cutter and leaving ragged ribbons along top edges. Jeton runs high-rake, wide-gullet single-flute carbide cutters with crisp compressed air cooling, avoids excessive clamping pressure that squeezes thin PP frames oval, and leaves conservative wall thickness ≥1.5 mm.
Design Rules for CNC Polypropylene & Transition to Molding
- Homopolymer PP-H vs. Copolymer PP-C: Use PP-H for maximum stiffness and chemical heat resistance; select PP-C for impact durability below 0°C (-20°C to -80°C cryo racks).
- Living Hinge Reality Check: CNC-machined PP living hinges fatigue faster than injection-molded flow-aligned hinges—specify ≥0.4 mm thickness with generous radius for CNC trials.
- Virgin ISO 13485 Material Traceability: Zero-regrind natural homopolymer PP stock with food/medical compliance documentation upon request.
- Scale-Up Path: Moves cleanly into S136 stainless molds for medical sampling tubes, syringes, and leak-proof screw caps.
Moving From CNC Polypropylene to High-Volume PP Injection Molding
Our cleanroom-ready Haitian presses mold virgin PP continuously with zero chemical mold-release sprays and -90 kPa leak testing for fluid vessels.